School District Litchfield Public School District 465, Litchfield, MN is seeking bids for E-Rate eligible services (FCC Form 470 #270005015, funding year 2027).
Services requested: Basic Maintenance Of Internal Connections; Internal Connections. Items: Wireless Access Points; Uninterruptable Power Supply/Battery Backup And Necessary Software And Licenses; Uninterruptable Power Supply/Battery Backup; Wireless Access Points And Necessary Software And Licenses.
Cat 2 internal connections equipment for wireless network refresh across one or more District buildings. Final scope determined at award based on available budget. Up to approximately 120 enterprise-grade indoor WAPs to replace existing access points in current locations; no new wiring is required. APs must support Wi-Fi 6 (802.11ax) or Wi-Fi 7 (802.11be). Models District reviewed include Extreme Networks AP510C / AP410C, HPE Aruba Networking AP-515/AP-615, AP-655, & AP-735, Ruckus R670, & Ubiquiti UniFi U7-Pro (& U7 Outdoor for exterior locations); any equivalent meeting these requirements is acceptable. Units must support centralized cloud-based or controller-based management, including provisioning of multiple SSIDs per access point, assignment of SSIDs to VLANs, & visibility into current & historical performance & connected devices. All required software, subscription, or management licensing necessary for operation & management must be included for a period of five years. 1 APC Smart-UPS C 1500VA RM 2U 120V with SmartConnect or equivalent UPS, approximately 1,500 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Include rack rails/mounting hardware & all required power cords. 3 APC Smart-UPS SMT2200RM2UC or equivalent UPS, approximately 2,200 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Include rack rails/mounting hardware & all required power cords. 3 Eaton 5PX3000RTN or equivalent UPS, approximately 3,000 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Include rack rails/mounting hardware & all required power cords. 3 APC Smart-UPS 750VA (SMT750RM2UC) or equivalent UPS, approximately 750 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Include rack rails/mounting hardware & all required power cords. 3 Eaton 9PX 5-6 kVA or equivalent UPS, approximately 5,000-6,000 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Online double-conversion design preferred. Include rack rails/mounting hardware & all required power cords. 3 APC Smart-UPS SMTL3000RM2UC (lithium-ion) or equivalent UPS, approximately 3,000 VA capacity or more, to provide conditioned & backup power for eligible internal network equipment. Line-interactive or online design with pure sine wave output; rack-mount form factor (rack/tower convertible acceptable); hot-swappable batteries; automatic voltage regulation; LCD status display; network management capability for remote monitoring & alerting; surge & overload protection; graceful shutdown capability for connected devices. Lithium-ion batteries required. Include rack rails/mounting hardware & all required power cords. 3 Eaton external battery modules compatible with Eaton 5PX / 9PX UPS systems being quoted, or equivalent, to extend UPS runtime. Rack-mountable; include all required interconnect cabling & mounting hardware; manufacturer warranty. All costs not eligible for E-Rate must be identified separately in your proposal. Costs not identified in proposal will be responsibility of vendor & will not be paid by school district or E-Rate program.
Bids must follow the E-Rate competitive bidding rules; the applicant may set an earlier response deadline in its RFP.